Product Description
Defender CA6150 + LL6270 Carbon Monoxide Alarm and Low-Level Monitor Kit
Standard carbon monoxide alarms are designed to stay quiet at low CO levels. That's how the UL 2034 standard works. The Defender CA6150 + LL6270 kit closes that gap. You get a UL 2034-listed CA6150 alarm for your code-required protection, plus the LL6270 low-level monitor, which shows CO from 5 ppm, flashes a warning at 9 ppm and sounds an alarm from 15 ppm, long before a standard alarm would react.
Buy both and save compared with buying the CA6150 and LL6270 separately.
The Gap a Standard CO Alarm Leaves
UL 2034 does not allow listed CO alarms to automatically display or sound below 30 ppm. At 70 ppm, a listed alarm is specified to sound within 60-240 minutes. For comparison, the EPA's outdoor air standard for CO is 9 ppm averaged over eight hours. That 70 ppm alarm point is nearly eight times higher. The WHO's 2021 guideline is lower still: 4 mg/m³ over 24 hours, about 3.5 ppm.
These are outdoor air-quality benchmarks, not alarm setpoints. But they show why a silent alarm doesn't mean your air is clean. The LL6270 is built for exactly that range, and the CA6150 keeps the listed alarm protection codes call for.
See It Tested: 50 PPM for 60 Minutes
We tested six carbon monoxide alarms and monitors at 50 ppm for 60 minutes. Watch to see which devices provided warnings and which remained silent, and why a listed alarm and a low-level monitor do different jobs.
Actual 60-minute test using 50 ppm NIST-traceable carbon monoxide calibration gas.
Why Buy Both?
- Code-required protection: The CA6150 is UL listed to ANSI/UL 2034, the standard building codes reference for residential CO alarms.
- Low-level early warning: The LL6270 shows CO on its display automatically from 5 ppm, flashes a red alert at 9 ppm and sounds an alarm from 15 ppm, with faster alarms as levels rise.
- Protection for the whole family: Defender designed the LL6270 for households with older adults, pregnant women, young children and people with medical conditions. They are typically the first affected by CO and the most exposed to lower levels.
- Know what happened while you were out: Once the LL6270 detects 9 ppm or more, its red light keeps flashing until the display reads 0 ppm for 7 days in a row. Both units also store peak readings and how long they lasted.
- No battery changes: Both units run on factory-sealed lithium batteries. Ten years for the CA6150, up to five years for the LL6270.
- Save with the kit: The kit costs less than buying both units separately.
What Is Included?
- One Defender CA6150 UL-listed residential carbon monoxide alarm
- One Defender LL6270 low-level carbon monoxide monitor
Each unit has its own mounting plate, controls and owner's manual. Follow each manual for mounting, activation, testing and operation.
Two Devices, Two Jobs
| Feature | CA6150 | LL6270 |
|---|---|---|
| Role | UL-listed residential CO alarm | Low-level CO monitor |
| Listing | UL listed to ANSI/UL 2034 | Not UL listed |
| Automatic display | 30-999 ppm | 5-500 ppm |
| Button readout / memory | Current level from 10 ppm; peak in last 30 days; peak duration | Peak in last 7 days from 5 ppm; peak duration |
| Low-level warnings | None; low readings by button press only | Red light at 9 ppm within 10 minutes; horn at 15 ppm within 60 minutes |
| Sampling | Every 10 seconds | Every 5 seconds |
| Power | Sealed lithium; ten years | Sealed lithium; up to five years |
| Replacement | Ten years from installation | Every three years recommended for display accuracy; end-of-life signal at five years |
| Limited warranty | Ten years, alarm and batteries | Three years, monitor and batteries |
Display and Alarm Timing
Both units respond to concentration and time. Here is when each one reacts.
| CO level | LL6270 | CA6150 |
|---|---|---|
| 5-29 ppm | Displays level within 1 minute | Silent; readout by button press from 10 ppm |
| 9-14 ppm | Red light flashes within 10 minutes | Silent |
| 15-24 ppm | Red light when detected; horn within 60 minutes | Silent |
| 25-49 ppm | Horn within 30 minutes | Silent; displays automatically from 30 ppm |
| 50-99 ppm | Horn within 15 minutes | Alarm within 60-240 minutes at 70 ppm |
| 100-149 ppm | Horn within 5 minutes | Alarm within 10-50 minutes at 150 ppm |
| 150 ppm and above | Horn when detected; cannot be muted | Alarm within 4-15 minutes at 400 ppm |
These are Defender's specified response points. The CA6150 values are its UL 2034 test points, not a claim that it can never alarm below 70 ppm. Follow each manual's instructions whenever either device alerts.
Is This Kit Right for Your Home?
Choose the kit if you want listed alarm protection and automatic low-level warning in one purchase, and a battery-powered, single-station alarm suits your property. Already have listed alarms you're happy with? Add the LL6270 on its own. Need only the listed alarm? View the CA6150.
Plan your coverage: Defender recommends a listed alarm outside each sleeping area and on every level, and a low-level monitor in or near every room people use, inside bedrooms of more vulnerable family members and near any room with fuel-burning equipment. Larger homes often need more than one kit, or additional LL6270 units.
The kit is two separate devices, not an interconnected system. If your local code requires hardwired or interconnected alarms, confirm what is needed before you install.
Shared Specifications
| Package | Two separate CO devices: CA6150 + LL6270 |
|---|---|
| Sensor type | Water-based electrochemical sensors with nuisance-gas filters |
| Audible signal | 85 dB at 10 feet (each) |
| Operating conditions | 40-100°F; 10-95% relative humidity |
| Instrument size / weight | Each: 5½ × 3¾ × 1â…œ inches / 8 oz |
| Housing / manufacture | White flame-retardant ABS / Canada |
Use in conditioned indoor locations. Neither unit detects smoke or other gases. Shipping dimensions and weight differ from the individual instrument measurements.
Frequently Asked Questions
Why not just buy the CA6150?
Because it is designed to stay silent at low levels. UL 2034 doesn't allow it to warn below 30 ppm, and at 70 ppm it can take up to four hours to sound. You can check low readings by pressing its button, but only if you think to look. The LL6270 watches those levels around the clock and warns you automatically.
Why not just buy the LL6270?
The LL6270 is not UL listed, so it can't replace a listed CO alarm where code requires one. Defender designed it to supplement a listed alarm, not substitute for it. The kit gives you both.
Does the kit meet building code?
The CA6150 carries the UL 2034 listing codes reference for residential CO alarms. Many jurisdictions accept battery-powered alarms in existing homes, while new construction and major remodels typically require alarms powered by the building's wiring with battery backup, interconnected when more than one is required. If the installation is for a permit or inspection, check with your local building department first.
Is the kit cheaper than buying both separately?
Yes. The kit is priced lower than buying the CA6150 and LL6270 individually.
Will the LL6270 sound at 5 ppm?
No. At 5 ppm it shows the reading on its display. The red light starts flashing at 9 ppm within 10 minutes, and the horn starts at 15 ppm within 60 minutes. Alarm times get shorter as CO rises.
Do both units last ten years?
No. The CA6150 runs for ten years and carries a ten-year limited warranty. The LL6270 carries a three-year limited warranty, and Defender recommends replacing it every three years to keep its display accurate. Its end-of-life signal comes on at five years.
How many kits do I need?
It depends on the size and layout of your home. At minimum, place a listed alarm outside each sleeping area and on every level, and place low-level monitors in or near the rooms your family uses most, especially bedrooms of young children, older adults or anyone with a medical condition. Many homes need more than one kit or extra LL6270 units.
Are the two units connected to each other?
No. They are separate single-station devices with no wired or wireless interconnection. If your installation requires interconnected alarms, the kit does not meet that requirement.
Manuals and Warranty
- Defender CA6150 Owner's Manual
- Defender CA6150 Quick Start Guide
- Defender LL6270 Owner's Manual
- Defender LL6270 Quick Start Guide
- Defender Warranty Service (CA6150)
- Defender Three-Year Limited Monitor Warranty (LL6270)