Product Description
Sensorcon Legacy Inspector Industrial Intrinsically Safe Carbon Monoxide Detector and CO Meter - INS-CO-02

The Sensorcon Legacy Inspector Industrial (INS-CO-02) is the original green-face Industrial model. It adds a vibrating alarm to the buzzer and LEDs and is intrinsically safe: it conforms to UL Std 913 and is certified to CSA Std C22.2 No. 157. It reads live CO from 0 to 1,999 ppm, alarms at 35 and 200 ppm, and carries a one-year Sensorcon warranty.
Reasons to Buy the Legacy Industrial
- Vibration plus sound and light: Feel the alarm when you can't hear it.
- Intrinsically safe: UL 913 / CSA C22.2 No. 157 (Intertek/ETL control no. 4004813).
- Live ppm display with MAX hold, 1 ppm resolution.
- Factory-set alarms at 35 and 200 ppm.
- Same sensor specifications as the Inspector 2 Industrial, with a one-year warranty.
On the Job
Loud environments: Around generators, compressors and running vehicles, the vibrating alarm signals at 35 ppm even when the buzzer is drowned out.
All-day wear: At 4 oz with a steel clip, it stays on a collar or pocket through a shift and shows the live level at a glance.
Legacy Industrial or Inspector 2 Industrial?
Both have the same sensor, alarms, vibration and intrinsic-safety certification. The Inspector 2 Industrial (INS2-CO-02) has a two-year warranty; the Legacy has one year. For adjustable alarms and TWA, see the Legacy Industrial Pro.
| Feature | Legacy Inspector INS-CO-01 |
Legacy Industrial INS-CO-02 |
Legacy Industrial Pro INS-CO-03 |
|---|---|---|---|
| Live CO number on screen | Yes | Yes | Yes |
| MAX reading | Yes | Yes | Yes |
| Audible and visual alarms | Yes | Yes | Yes |
| Vibration alert | — | Yes | Yes |
| Alarm points | 35 / 200 ppm | 35 / 200 ppm | Adjustable |
| TWA | — | — | Yes |
| UL 913 / CSA C22.2 No. 157 | — | Yes | Yes |
| Sensorcon warranty | 1 year | 1 year | 1 year |
| Inspector 2 equivalent | INS2-CO-01 | INS2-CO-02 | INS2-CO-03 |
| Product page | View | View | View |
Technical Specifications
| Model | Sensorcon Legacy Inspector Industrial INS-CO-02 (portable) |
|---|---|
| Sensor | Electrochemical |
| Range (measure / display) | 0-500 ppm / 0-1,999 ppm |
| Reads in | 1 ppm increments |
| Accuracy (per Sensorcon) | Within 10% of the reading from 0-500 ppm; within 2 ppm under 20 ppm |
| Response time | <5 s / <20 s |
| Alarm levels | 35 ppm low, 200 ppm high (factory set) |
| Alarm outputs | 80-85 dB buzzer, four flashing red LEDs, on-screen alarm icons; vibration |
| Programmable alarms | Not adjustable |
| Time-weighted average (TWA) | None |
| Intrinsic safety | Conforms to UL Std 913; certified to CSA Std C22.2 No. 157 (Intertek/ETL control no. 4004813) |
| Compliance | CE marked |
| Cell | Single CR123A; about two years of typical use |
| Operating temperature | -4 to 122°F |
| Relative humidity | 20-90% RH continuous; 0-99% RH intermittent |
| Case | Water-resistant, shock-resistant case |
| Size and weight | About 3.2 by 2.2 by 0.86 in, 4 oz |
| Attachment | Steel clip and lanyard loop |
| Calibration | Depends on the frequency of its use, the environment it's used in, and how it's stored when not in use; EOL symbol at 2 years, cleared for 180 days by each successful calibration. See manufacturer recommendations for further details. |
| Coverage | One-year Sensorcon limited warranty |
| Assembled | Assembled in the United States |
Frequently Asked Questions
What does intrinsically safe mean here?
This model conforms to UL Std 913 and is certified to CSA Std C22.2 No. 157 (Intertek/ETL control no. 4004813). Intrinsically safe means the electronics are designed so that no internal fault can release enough energy to set off a flammable atmosphere. Do not remove the battery or service the unit in a potentially explosive atmosphere. Confirm the certification against your site's requirements.
Is IND-02 the same product as INS-CO-02?
Yes. INS-CO-02 is Sensorcon's model number for the Legacy Inspector Industrial. IND-02 is how this listing has been labeled on our site.
Can I calibrate it myself?
Yes, with 50 ppm CO calibration gas, a regulator and tubing at 0.3-0.5 L/min. The steps are in the manual below. How often depends on the frequency of its use, the environment it's used in, and how it's stored when not in use, and your safety program may ask for bump tests. See manufacturer recommendations for further details.
How do I capture a peak reading?
Tap MAX. An arrow appears over the word MAX and the screen holds the highest value until a higher one comes along. Tap again to return to live readings.
How long does the battery last?
Around two years on a CR123A lithium cell, less if the alarms sound often. The display shows a battery icon when it is time for a new one.
Who services it?
Sensorcon offers a $49 calibration service with free return shipping and a $69 renewal that replaces the sensor and battery and renews the warranty. Prices are set by Sensorcon.
Manuals, Warranty and Service
- Sensorcon Inspector and Inspector 2 Instruction Manual (PDF)
- Sensorcon Inspector Series Brochure (PDF)
- Sensorcon Warranty, Repairs and Returns
- Sensorcon Calibration Service
Sensorcon · Built to be rebuilt
Own a Professional-Grade CO Monitor for Less Than $50 a Year
Buy it once. Rebuild it for years.
Why throw away a disposable CO detector when you can rebuild it for just $69?
*Example based on the Sensorcon Legacy Inspector (INS-CO-01): $154 + two $69 Sensorcon rebuilds over six years. Prices subject to change.
AV8
Inspector 2
Legacy*