Product Description
Sensorcon H2S Sampling Kit: Hand Pump and Case for Hydrogen Sulfide Inspector Meters
The Sensorcon H2S Sampling Kit adds a hand-aspirated pump with inline filter and a carrying case to a Sensorcon Hydrogen Sulfide Inspector (INS2-H2S-03). The pump draws air from hard-to-reach areas to the sensor. Meter not included. This kit is for H2S models only; for CO Inspectors, see the CO sampling kit.
What's in the Kit
- Hand-aspirated pump assembly with inline filter
- Carrying case
How to Sample
Fit the pump to the H2S meter's inlet, hold the probe where you want to test, and pump steadily, roughly one squeeze per 1-2 seconds, for 15-20 seconds before reading the display.
About the H2S Inspector
Sensorcon's Inspector Industrial Pro H2S (INS2-H2S-03) measures 0-400 ppm hydrogen sulfide with factory alarm points of 10 ppm low and 15 ppm high, adjustable from 1-20 ppm (low) and 11-100 ppm (high).
Frequently Asked Questions
Does this include an H2S meter?
No. The kit is the pump assembly and case only.
Can I use it with a CO Inspector?
No. Use the CO sampling kit for CO models.
Sensorcon · Calibration service
$49 keeps your Sensorcon job-ready.
New battery included. Every Legacy Inspector, Inspector 2 and AV8 model.