Standard Equipment Includes:
- Insulation multimeter
- Remote probe
- Test leads
- Alligator clips
- Hard case
- Four AA alkaline batteries
- Quick Reference Guide
- CD Rom with Manual
Two powerful tools in one
The
Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester
with a full-featured, true RMS digital multimeter in a single, compact, handheld
unit, which provides maximum versatility for both troubleshooting and
preventative maintenance.
Whether you work on motors, generators, cables,
or switch gear, the Fluke 1587/1577 Insulation Multimeters are ideally suited to
help you with your tasks and at a cost that is far less than buying the two
products.
- Voltage DC:
- Maximum Voltage: 1000 V
- Accuracy:
- 1577: ±(0.2%+2)
- 1587: ±(0.09%+2)
- Maximum Resolution: 0.001V
- Voltage AC:
- Maximum Voltage: 1000 V
- Accuracy:
- 1577: ±(2%+3)
- 1587: ±(2%+3)
- AC Bandwidth: 1587: 5kHz* *with low pass filter; 3db @ 800 Hz
- Maximum Resolution: 0.1 mV
- Current DC:
- Maximum Amps: 400mA
- Amps Accuracy:
- 1577: ±(1.0%+2)
- 1587: ±(0.2%+2)
- Maximum Resolution: 0.01 mA
- Current AC:
- Maximum Amps: 400mA
- Amps Accuracy:
- 1577: ±(2.0%+2)*
- 1587: ±(1.5%+2)*
* 1kHz bandwidth
- Maximum Resolution: 0.01 mA
- Resistance:
- Maximum Resistance: 50 MΩ
- Accuracy:
- 1577: ±(1.2%+2)
- 1587: ±(0.9%+2)
- Maximum Resolution: 0.1Ω
- Capacitance(1587 only):
- Maximum Capacitance: 9,999 µF
- Accuracy: ±(1.2%+2)
- Maximum Resolution: 1 nF
- Frequency (1587 only):
- Maximum Frequency: 100 kHz
- Accuracy: ±(0.1%+1)
- Maximum Resolution: 0.01 Hz
- Temperature Measurement (1587 only):
- -40.0°C to 537°C
- -40.0°F to 998°F
excluding probe
- Diode Test (1587 only):
- Range: 6 V
- Resolution: 1 mV
- Accuracy: ±(2% + 1)
Insulation
Test
- Minimum Test Current @ 1kΩ/V:
- Test Voltages:
- 1577: 500, 1000 V
- 1587: 50, 100, 250, 500, 1000 V
- Maximum Resistance per Test Voltage:
- 50V:
- 100V:
- 250V:
- 500V:
- 1000V:
- Maximum Resolution per Test Voltage:
- 50V: 0.01 MΩ
- 100V: 0.01 MΩ
- 250V: 0.1 MΩ
- 500V: 0.1 MΩ
- 1000V: 0.1 MΩ
- Accuracy per Test Voltage:
- 50V: ±(3 % + 5)
- 100V: ±(3% + 5)
- 250V: ±(1.5% + 5)
- 500V:
- 1577: ±(2.0% + 5)
- 1587: ±(1.5% + 5)
- 1000V:
- 1577: ±(2.0% + 5)
- 1587: ±(1.5% + 5) to 600 MΩ, ±(10% + 3) above 600
MΩ
Environmental Specifications
- Operating temperature: –20°C to +55°C
- Storage temperature: -40°C to +60°C
- Humidity (Without Condensation):
- 0% - 95% (10°C – 30°C)
- 0% - 75% (30°C – 40°C)
- 0% - 40% (40°C – 55°C)
- Operating Altitude: 2000 m
Safety Specifications:
- Overvoltage category: Complies with ANSI/ISA 82.02.01 (61010-1) 2004,
CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT
III 1000 V and CAT IV 600 V
- Agency Approvals: 2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II
1000 V, CAT III 600 V
Mechanical & General
Specifications:
- Size: 203 x 100 x 50 mm (with holster)
- Weight: 624 g
- Warranty: 3 years
- Battery life: Alkaline Meter use: 1000 hours Insulation test use:
Meter can perform at least 1000 insulation tests with fresh alkaline batteries
at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty
cycle of 5 seconds on and 25 seconds off.
- IP Rating: IP40
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Features
- Insulation test voltages 500V, 1000V
- Insulation test: 0.01 MΩ to 2.0 GΩ
- Auto discharge of capacitive voltage
- AC/DC Voltage
- DC millivolts
- AC/DC milliamps
- Resistance (0.1 Ω to 50 MΩ)
- Continuity
- Three-year warranty
- Remote probe, test leads, alligator clips
- Rugged, utility hard case
- Auto power off to save battery power
- True-rms
- Large display with backlight
- Live circuit detection prevents insulation test if voltage > 30 V is
detected for added user protection
- CAT III 100V, CAT IV 600V measurement category
- Accepts optional Fluke TPAKTM magnetic
hanging system to free your hands for other work
|
|
 |
 |
 |
 |

|