All-in-One refrigerant leak detector
Features:
- Detects all CFC, HFC, and HCFC Refrigerants
- Manual or automatic, auto zero balance control
- Pass / Fail test mode
- Unique sensor calibration system
- CE Mark
- Pinpoints both small and large leaks
Specifications
Detects All CFC, HFC, and HCFC Refrigerants
Sensing Element Positive Ion Emission Heated Diode
Sensitivity Moving probe test per SAE Std. J1627
Alarm Sensitivity
R-134a:
• Small - 0.5 oz/year
• Medium - 1.0 oz/year
• Large - 5.0 oz/year
R-12:
• Small - 0.1 oz/year
• Medium - 0.5 oz/year
• Large - 3.0 oz/year
Warm-Up Time Approximately 2 minutes
Accuracy Exceeds SAE J1627
Probe Length 4.5 feet
Dimensions 5.5" x 10.5" x 8.5"
Weight 5 lbs
Agency Listings UL file SA917, SAE J1627, CE Mark
Power
- 12 VDC - internal rechargeable, sealed lead acid battery
- 12 VDC - external battery using battery clamp/cigarette lighter plug
- 120 VAC - wall adapter to charge battery only
- 120 VAC - optional wall adapter to charge-and-run unit continuously
Leak Alarm Audible alarm and visible neon lamp
Response Time Approximately 1 sec. |
|
 |
 |
|
 |

|